- R4,263 Add to cart
- R10,919 Add to cart
- R11,840 Add to cart
- Description Specification Paint pot capacity 20 litres Working pressure 1.4 – 2.1 Bar Feed type Pressure feed Max pressure 6.3 Bar Air inlet thread 1/4 BSP Fluid hose outlet thread 3/8 BSP Agitator Automatic Tips and techniques When sprayfinishing, it’s always advised to keep the spray gun parallel to the workpiece surface. The distance from the surface of the workpiece should be the width of the spray pattern. The lower the pressure of the air, the lower the chance to have bounce-back (overspray). The pressure should only be increased when the spray pattern is uneven – paint focused in the middle when the fan setting is wide.
20 Lt Automatic Mix Paint Pot Only
R12,138R12,138 Add to cart - R4,605 Add to cart
- R67,953 Add to cart
- Description General Characteristics: Model Name APD 200 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A6CRX71TI Alternator Made and Model Aksa – AK 4150 Control Panel Model DSE 6120 Canopy ACP 6B 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 200 160.00 182 145.60 288.68 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A6CRX71TI NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 110 X 125 TOTAL DISPLACEMENT L 7.13 Aspiration Turbo Charged and Intercooled(Water to Air) COMPRESSION RATIO 17:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16 Standby Power (kW/HP) 182/247.45 Prime Power 166/225.7 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump P pump Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×80 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 190 Coolant Capacity (engine only / with radiator) (lt) 9,55/38 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 42.5 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4150 Frequency (Hz) Hz 50 Power (kVA) kVA 187.5 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 580 COOLING AIR (m³/min) m3 30,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 6B 2180 3265 1163 1858 271
200KVA GENERATOR
R476,987R476,987 Add to cart - Description General characteristics: Model Name APD 200 C Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – 6CTA8.3-G2 Alternator Made and Model Aksa – AK 4150 Control Panel Model DSE 6120 Canopy AK 49 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 200 160 180 144 288.68 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model 6CTA8.3-G2 NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 114 X 135 TOTAL DISPLACEMENT L 8,30 Aspiration Turbo Charged and AfterCooled COMPRESSION RATIO 17.3:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16,6 Standby Power (kW/HP) 180/241 Prime Power 163/218 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump BYC PB Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×85 Charge Alternator (A) 40 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 278 Coolant Capacity (engine only / with radiator) (lt) 12.3/41.3 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 42 Fuel Cons. Prime With %75 Load (lt/hr) 31 Fuel Cons. Prime With %50 Load (lt/hr) 21 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4150 Frequency (Hz) Hz 50 Power (kVA) kVA 187.5 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 580 COOLING AIR (m³/min) m3 30,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 1880 2600 1250 1684 473 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) AK 49 2140 3404 1136 2020 340
200KVA GENERATOR
R645,795R645,795 Add to cart