- R2,779 Add to cart
- Description General Characteristics: Model Name APD 145 C Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – 6BTAA5.9-G2 Alternator Made and Model Aksa – AK 4110 Control Panel Model DSE 6120 Canopy AK 49 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 145 116 132 105.60 209.30 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model 6BTAA5.9-G2 NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 102 X 120 TOTAL DISPLACEMENT L 5.90 Aspiration Turbo Charged and Charge Air Cooled COMPRESSION RATIO 17.3:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16.4 Standby Power (kW/HP) 130/174 Prime Power 120/161 Block Heater QTY 1 Block Heater Power (Watt) 1000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump BYC PB Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×66 Charge Alternator (A) 40 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 148 Coolant Capacity (engine only / with radiator) (lt) 10/54 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 30 Fuel Cons. Prime With %75 Load (lt/hr) 23 Fuel Cons. Prime With %50 Load (lt/hr) 16 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4110 Frequency (Hz) Hz 50 Power (kVA) kVA 137,5 Design Brushless Voltage V 400 Phase 3 A.V.R. AS460 Voltage Regulation (+/-) 1,5% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 492 COOLING AIR (m³/min) m3 30,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 1360 2290 1000 1474 195 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) AK 49 1780 3404 1136 2020 340
145KVA GENERATOR
R402,207R402,207 Add to cart - R8,867 Add to cart
- R35,937 Add to cart
- R4,085 Add to cart
- Description General Characteristics: Model Name APD 165 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A6CRX65TI Alternator Made and Model Aksa – AK 4120 Control Panel Model DSE 6120 Canopy ACP 6B 3 Phase, 50Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 165 132.00 150 120.00 238.16 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A6CRX65TI NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 105 X 125 TOTAL DISPLACEMENT L 6,49 Aspiration Turbo Charged and Intercooled(Water to Air) COMPRESSION RATIO 17:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16 Standby Power (kW/HP) 153/208.02 Prime Power 139/188.99 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump PM pump Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×80 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 190 Coolant Capacity (engine only / with radiator) (lt) 6,35/38 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 34.3 Alternator Specifications: Manufacturer – Aksa Alternator Made and Model – AK 4120 Frequency (Hz) – 50Hz Power (kVA) – 150Kva Design – 4 Pole, Brushless Voltage – 400V Phase – 3 A.V.R. – SX460 Voltage Regulation – (+/-)1,5% Insulation System – H Protection – IP23 Rated Power Factor – 0.8 WEIGHT COMP. GENERATOR – 492Kg COOLING AIR (m³/min) – 30,84m3 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 6B 2070 3265 1163 1858 271
165KVA GENERATOR
R342,942R342,942 Add to cart - R3,868 Add to cart
- R3,868 Add to cart