17–32 of 5185 Results

Sort by:
  • 10 Lt Automatic Mix Paint Pot Only
    Sku: SG PP10-2

    10 Lt Automatic Mix Paint Pot Only

    R10,079
  • 10 Lt Manual Mix Paint Pot
    Sku: SG PP10

    10 Lt Manual Mix Paint Pot

    R7,757
  • 1000 Litre Horizontal Water Storage Tank
    Sku: 1000HORMJJG

    1000 Litre Horizontal Water Storage Tank

    R9,568
  • 1000 Litre Slimline Standard Water Storage Tank
    Sku: 1000SLMBWIN

    1000 Litre Slimline Standard Water Storage Tank

    R5,156
  • 10000 Litre Vertical Water Storage Tank
    Sku: 10000WAJJG

    10000 Litre Vertical Water Storage Tank

    R27,943
  • 10L Paint Pot With 2M Hose And Gun No Cup
    Sku: SG PPX1

    10L Paint Pot With 2M Hose And Gun No Cup

    R6,351
  • 10Mm Composite Straight Drill Keyless Chuck
    Sku: KBE2706050K

    10Mm Composite Straight Drill Keyless Chuck

    R3,935
  • 11 Bay Bulk Filer
    Sku: 11BBF400

    11 Bay Bulk Filer

    R87,782
  • 11-Drawer Extra Large Topchest
    Sku: KEN5945780K

    11-Drawer Extra Large Topchest

    R25,298
  • Description General Characteristics: Model Name AC 1100 K Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – KTA38-G14 Alternator Made and Model Mecc Alte – ECO 43-1M/4 A Control Panel Model DSE 7320 Canopy AK 96 3 Phase, 50 Hz, PF0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 1100 880.0 1000 800.0 1587.76 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model KTA38-G14 NO. OF CYLINDERS AND BUILD 12 cylinders – V type BORE AND STROKE mm 159 X 159 TOTAL DISPLACEMENT L 37.8 Aspiration Turbo Charged and After Cooled COMPRESSION RATIO 13.9:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 135 Standby Power (kW/HP) 970/1300 Prime Power 880/1180 Block Heater QTY 2 Block Heater Power (Watt) 3000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump Cummins PT Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 4×120 Charge Alternator (A) 35 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 1489 Coolant Capacity (engine only / with radiator) (lt) 124/350 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 209 Fuel Cons. Prime With %75 Load (lt/hr) 161 Fuel Cons. Prime With %50 Load (lt/hr) 113 Alternator Specifications: Manufacturer Mecc Alte Alternator Made and Model ECO 43-1M/4 A Frequency (Hz) Hz 50 Power (kVA) kVA 1025 Design   4 Pole,  Brushless Voltage V 400 Phase 3 A.V.R. DER1 Voltage Regulation (+/-) 0.5% Insulation System H Protection IP23 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 2275 COOLING AIR (m³/min) m3 90 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 8600 4366 1770 2370 1500 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) AK 96 12250 7500 2300 2508 1500
    Sku: AC1100K

    1100KVA GENERATOR

    R4,140,630
  • Description General Characteristics: Model Name APD 110 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A4CRX46TI Alternator Made and Model Aksa – AK 480 Control Panel Model DSE 6120 Canopy ACP 6 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 110 88.00 100 80.00 158.78 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A4CRX46TI NO. OF CYLINDERS AND BUILD 4 cylinders – in line BORE AND STROKE mm 110 X 125 TOTAL DISPLACEMENT L 4,58 Aspiration Turbo Charged and Intercooled(Water to Air) COMPRESSION RATIO 17:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 14 Standby Power (kW/HP) 102/138.68 Prime Power 93/126.44 Block Heater QTY 1 Block Heater Power (Watt) 1000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump PM pump Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×60 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 132 Coolant Capacity (engine only / with radiator) (lt) 6/24 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 23 Alternator Specifications: Manufacturer – Aksa Alternator Made and Model – AK 480 Frequency (Hz) – 50Hz Power (kVA) – 100KVA Design – Brushless Voltage – 400V Phase – 3 A.V.R. – SX460 Voltage Regulation – (+/-)1% Insulation System – H Protection – IP22 Rated Power Factor – 0.8 WEIGHT COMP. GENERATOR – 406Kg COOLING AIR (m³/min)m330,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 6 1685 2390 1058 1681 155
    Sku: APD110A

    110KVA GENERATOR

    R383,580
  • Description General Characteristics: Model Name APD 110 C Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – 6BT5.9-G2 Alternator Made and Model Aksa – AK 480 Control Panel Model DSE 6120 Canopy ACP 6A 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 110 88 100 80 158.78 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model 6BT5.9-G2 NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 102 X 120 TOTAL DISPLACEMENT L 5,90 Aspiration Turbo Charged COMPRESSION RATIO 17.3:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 13 Standby Power (kW/HP) 92/123 Prime Power 86/115 Block Heater QTY 1 Block Heater Power (Watt) 1000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump BYC A Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×66 Charge Alternator (A) 40 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 136 Coolant Capacity (engine only / with radiator) (lt) 7.9/35.9 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 22 Fuel Cons. Prime With %75 Load (lt/hr) 17 Fuel Cons. Prime With %50 Load (lt/hr) 11 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 480 Frequency (Hz) Hz 50 Power (kVA) kVA 100 Design   Brushless Voltage V 400 Phase 3 A.V.R. SX460 Voltage Regulation (+/-) 1% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 406 COOLING AIR (m³/min) m3 30,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 1280 2150 1000 1469 195 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 6A 1480 2600 1058 1590 180
    Sku: APD110C

    110KVA GENERATOR

    R475,419
  • 12 Bay Bulk Filer
    Sku: 12BBF400

    12 Bay Bulk Filer

    R105,338