- Description General Characteristics: Model Name AD 330 Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model HYUNDAI – P126TI-II Alternator Made and Model Aksa – AK 5240 Control Panel Model DSE 7320 Canopy MS 60 3 Phase, 50 Hz, PF0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 330 264.00 300 240.00 476.33 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine HYUNDAI Engine Model P126TI-II NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 123 X 155 TOTAL DISPLACEMENT L 11.051 Aspiration Turbo Charged and Intercooled (Air to Air) COMPRESSION RATIO 17.1:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 23 Standby Power (kW/HP) 294/400 Prime Power 265/360 Block Heater QTY 1 Block Heater Power (Watt) 3000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump Zexel P inline Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×85 Charge Alternator (A) 45 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 450 Coolant Capacity (engine only / with radiator) (lt) 19/43 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 63.1 Fuel Cons. Prime With %75 Load (lt/hr) 47 Fuel Cons. Prime With %50 Load (lt/hr) 31.3 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 5240 Frequency (Hz) Hz 50 Power (kVA) kVA 300 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1 Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 940 COOLING AIR (m³/min) m3 29.16 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 2410 2868 1300 1787 470 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) MS 60 3100 3934 1356 2156 470
330KVA GENERATOR
R842,231R842,231 Add to cart - Description General Characteristics: Model Name APD 35 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A4CRX36 Alternator Made and Model Aksa – AK 228 Control Panel Model DSE 6120 Canopy ACP 3A 3 Phase 50Hz, PF 0.8 Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper kVA kW kVA kW 400/231 35 28.00 32 25.60 50.52 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine – AKSA Engine Model – A4CRX36N NO.OF CYLINDERS AND BUILD – 4 cylinders – in line BORE AND STROKE – 98 X 120MM TOTAL DISPLACEMENT – 3.6L Aspiration – Naturally Aspirated COMPRESSION RATIO – 18:1 RATED SPEED (RPM) d/dk – 1500 OIL CAPACITY – 10L Standby Power (kW/HP) – 33/44.8 Prime Power – 30/40.7 Block Heater QTY – 1 Block Heater Power (Watt) – 500 Fuel Type – Diesel Injection Type and System – Direct Type of Fuel Pump – Direct Governor System – Mechanic Operating Voltage (Vdc) – 12 Vdc Battery and Capacity (Qty/Ah) – 1×54 Cooling Method – Water Cooled Cooling Fan Air Flow (m3/min) – 180 Coolant Capacity (engine only / with radiator) (lt) – 9/20 Air Filter – Dry Type Fuel Cons. Prime With %100 Load (lt/hr) – 8.04 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 228 Frequency (Hz) Hz 50 Power (kVA) kVA 35 Design 4 Pole, Brushless Voltage V 400 Phase 3 A.V.R. FD460 Voltage Regulation (+/-) 1% Insulation System H Protection IP23 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 167.5 COOLING AIR (m³/min) m3 12.96 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 3A 810 1980 950 1128 60
35KVA GENERATOR
R208,605R208,605 Add to cart - Description General Characteristics: Model Name APD 360 C Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – 6LTAA9.5-G1 Alternator Made and Model Aksa – AK 5280 Control Panel Model DSE 7320 Canopy MS 60 CK 3 Phase, 50 Hz, PF0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 360 288.00 327 261.60 519.63 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model 6LTAA9.5-G1 NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 116.5 X 148 TOTAL DISPLACEMENT L 9.50 Aspiration Turbo Charged and Charge Air Cooled COMPRESSION RATIO 16.6:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 32.4 Standby Power (kW/HP) 320/429 Prime Power 290/389 Block Heater QTY 1 Block Heater Power (Watt) 3000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump Mechanical Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×85 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 708 Coolant Capacity (engine only / with radiator) (lt) 11.1/65.1 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 70 Fuel Cons. Prime With %75 Load (lt/hr) 52 Fuel Cons. Prime With %50 Load (lt/hr) 35 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 5280 Frequency (Hz) Hz 50 Power (kVA) kVA 3500 Design 4 Pole, Brushless Voltage V 400 Phase 3 A.V.R. MX341 Voltage Regulation (+/-) %1 Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 1024 COOLING AIR (m³/min) m3 48 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 2750 2840 1300 1845 470 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) MS 60 CK 3480 3963 1356 2171 470
360KVA GENERATOR
R947,808R947,808 Add to cart - Maximum 5.0kVA Standby, 230V, 3000 RPM 15 litre tank: 8 Hours runtime @ 75% load Built-in AVR delivers non-fluctuating power 12v Electric Starter Single cylinder: vertical, direct injection Powerful Diesel Engine Single Phase Output 4.5kVA Prime Silent Diesel Generator
4.5KVA Diesel Generator Single Phase
R33,591R33,591 Add to cart - R13,939 Add to cart
- R13,144 Add to cart