- Description General Characteristics: Model Name AC 1100 K Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – KTA38-G14 Alternator Made and Model Mecc Alte – ECO 43-1M/4 A Control Panel Model DSE 7320 Canopy AK 96 3 Phase, 50 Hz, PF0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 1100 880.0 1000 800.0 1587.76 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model KTA38-G14 NO. OF CYLINDERS AND BUILD 12 cylinders – V type BORE AND STROKE mm 159 X 159 TOTAL DISPLACEMENT L 37.8 Aspiration Turbo Charged and After Cooled COMPRESSION RATIO 13.9:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 135 Standby Power (kW/HP) 970/1300 Prime Power 880/1180 Block Heater QTY 2 Block Heater Power (Watt) 3000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump Cummins PT Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 4×120 Charge Alternator (A) 35 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 1489 Coolant Capacity (engine only / with radiator) (lt) 124/350 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 209 Fuel Cons. Prime With %75 Load (lt/hr) 161 Fuel Cons. Prime With %50 Load (lt/hr) 113 Alternator Specifications: Manufacturer Mecc Alte Alternator Made and Model ECO 43-1M/4 A Frequency (Hz) Hz 50 Power (kVA) kVA 1025 Design 4 Pole, Brushless Voltage V 400 Phase 3 A.V.R. DER1 Voltage Regulation (+/-) 0.5% Insulation System H Protection IP23 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 2275 COOLING AIR (m³/min) m3 90 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 8600 4366 1770 2370 1500 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) AK 96 12250 7500 2300 2508 1500
1100KVA GENERATOR
R3,588,546R3,588,546 Add to cart - Description General Characteristics: Model Name APD 110 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A4CRX46TI Alternator Made and Model Aksa – AK 480 Control Panel Model DSE 6120 Canopy ACP 6 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 110 88.00 100 80.00 158.78 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A4CRX46TI NO. OF CYLINDERS AND BUILD 4 cylinders – in line BORE AND STROKE mm 110 X 125 TOTAL DISPLACEMENT L 4,58 Aspiration Turbo Charged and Intercooled(Water to Air) COMPRESSION RATIO 17:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 14 Standby Power (kW/HP) 102/138.68 Prime Power 93/126.44 Block Heater QTY 1 Block Heater Power (Watt) 1000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump PM pump Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×60 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 132 Coolant Capacity (engine only / with radiator) (lt) 6/24 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 23 Alternator Specifications: Manufacturer – Aksa Alternator Made and Model – AK 480 Frequency (Hz) – 50Hz Power (kVA) – 100KVA Design – Brushless Voltage – 400V Phase – 3 A.V.R. – SX460 Voltage Regulation – (+/-)1% Insulation System – H Protection – IP22 Rated Power Factor – 0.8 WEIGHT COMP. GENERATOR – 406Kg COOLING AIR (m³/min)m330,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 6 1685 2390 1058 1681 155
110KVA GENERATOR
R332,436R332,436 Add to cart - Description General Characteristics: Model Name APD 110 C Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – 6BT5.9-G2 Alternator Made and Model Aksa – AK 480 Control Panel Model DSE 6120 Canopy ACP 6A 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 110 88 100 80 158.78 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model 6BT5.9-G2 NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 102 X 120 TOTAL DISPLACEMENT L 5,90 Aspiration Turbo Charged COMPRESSION RATIO 17.3:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 13 Standby Power (kW/HP) 92/123 Prime Power 86/115 Block Heater QTY 1 Block Heater Power (Watt) 1000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump BYC A Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×66 Charge Alternator (A) 40 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 136 Coolant Capacity (engine only / with radiator) (lt) 7.9/35.9 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 22 Fuel Cons. Prime With %75 Load (lt/hr) 17 Fuel Cons. Prime With %50 Load (lt/hr) 11 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 480 Frequency (Hz) Hz 50 Power (kVA) kVA 100 Design Brushless Voltage V 400 Phase 3 A.V.R. SX460 Voltage Regulation (+/-) 1% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 406 COOLING AIR (m³/min) m3 30,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 1280 2150 1000 1469 195 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 6A 1480 2600 1058 1590 180
110KVA GENERATOR
R412,029R412,029 Add to cart - Description General Characteristics: Model Name APD 145 C Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – 6BTAA5.9-G2 Alternator Made and Model Aksa – AK 4110 Control Panel Model DSE 6120 Canopy AK 49 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 145 116 132 105.60 209.30 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model 6BTAA5.9-G2 NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 102 X 120 TOTAL DISPLACEMENT L 5.90 Aspiration Turbo Charged and Charge Air Cooled COMPRESSION RATIO 17.3:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16.4 Standby Power (kW/HP) 130/174 Prime Power 120/161 Block Heater QTY 1 Block Heater Power (Watt) 1000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump BYC PB Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×66 Charge Alternator (A) 40 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 148 Coolant Capacity (engine only / with radiator) (lt) 10/54 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 30 Fuel Cons. Prime With %75 Load (lt/hr) 23 Fuel Cons. Prime With %50 Load (lt/hr) 16 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4110 Frequency (Hz) Hz 50 Power (kVA) kVA 137,5 Design Brushless Voltage V 400 Phase 3 A.V.R. AS460 Voltage Regulation (+/-) 1,5% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 492 COOLING AIR (m³/min) m3 30,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 1360 2290 1000 1474 195 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) AK 49 1780 3404 1136 2020 340
145KVA GENERATOR
R522,869R522,869 Add to cart - Description General Characteristics: Model Name APD 165 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A6CRX65TI Alternator Made and Model Aksa – AK 4120 Control Panel Model DSE 6120 Canopy ACP 6B 3 Phase, 50Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 165 132.00 150 120.00 238.16 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A6CRX65TI NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 105 X 125 TOTAL DISPLACEMENT L 6,49 Aspiration Turbo Charged and Intercooled(Water to Air) COMPRESSION RATIO 17:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16 Standby Power (kW/HP) 153/208.02 Prime Power 139/188.99 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump PM pump Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×80 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 190 Coolant Capacity (engine only / with radiator) (lt) 6,35/38 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 34.3 Alternator Specifications: Manufacturer – Aksa Alternator Made and Model – AK 4120 Frequency (Hz) – 50Hz Power (kVA) – 150Kva Design – 4 Pole, Brushless Voltage – 400V Phase – 3 A.V.R. – SX460 Voltage Regulation – (+/-)1,5% Insulation System – H Protection – IP23 Rated Power Factor – 0.8 WEIGHT COMP. GENERATOR – 492Kg COOLING AIR (m³/min) – 30,84m3 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 6B 2070 3265 1163 1858 271
165KVA GENERATOR
R445,824R445,824 Add to cart - Description General Characteristics: Model Name APD 17 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A4CRX21 Alternator Made and Model Aksa – AK 113 Control Panel Model DSE 6120 Canopy ACP 1A 3 Phase,50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper kVA kW kVA kW 400/231 17 13.60 16 12.80 24.54 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A4CRX21 NO. OF CYLINDERS AND BUILD 4 cylinders – in line BORE AND STROKE mm 85 X 95 TOTAL DISPLACEMENT L 2.156 Aspiration Naturally Aspirated COMPRESSION RATIO 18:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 5.5 Standby Power (kW/HP) 16.7/22.4 Prime Power 15.2/20.4 Block Heater QTY 1 Block Heater Power (Watt) 500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump Direct Governor System Mechanic Operating Voltage (Vdc) 12 Vdc Battery and Capacity (Qty/Ah) 1×36 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 112.64 Coolant Capacity (engine only / with radiator) (lt) 5.5/16.8 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 4.59 Fuel Cons. Prime With %75 Load (lt/hr) 3.54 Fuel Cons. Prime With %50 Load (lt/hr) 2.6 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 113 Frequency (Hz) Hz 50 Power (kVA) kVA 16,3 Design Brushless Voltage V 400 Phase 3 A.V.R. SX460 Voltage Regulation (+/-) 1,5% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 109 COOLING AIR (m³/min) m3 4,26 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 405 1400 760 912 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 1A 535 1672 823 873 32
17KVA GENERATOR
R169,712R169,712 Add to cart - Description General Characteristics: Model Name APD 200 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A6CRX71TI Alternator Made and Model Aksa – AK 4150 Control Panel Model DSE 6120 Canopy ACP 6B 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 200 160.00 182 145.60 288.68 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A6CRX71TI NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 110 X 125 TOTAL DISPLACEMENT L 7.13 Aspiration Turbo Charged and Intercooled(Water to Air) COMPRESSION RATIO 17:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16 Standby Power (kW/HP) 182/247.45 Prime Power 166/225.7 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump P pump Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×80 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 190 Coolant Capacity (engine only / with radiator) (lt) 9,55/38 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 42.5 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4150 Frequency (Hz) Hz 50 Power (kVA) kVA 187.5 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 580 COOLING AIR (m³/min) m3 30,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 6B 2180 3265 1163 1858 271
200KVA GENERATOR
R476,987R476,987 Add to cart - Description General characteristics: Model Name APD 200 C Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – 6CTA8.3-G2 Alternator Made and Model Aksa – AK 4150 Control Panel Model DSE 6120 Canopy AK 49 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 200 160 180 144 288.68 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model 6CTA8.3-G2 NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 114 X 135 TOTAL DISPLACEMENT L 8,30 Aspiration Turbo Charged and AfterCooled COMPRESSION RATIO 17.3:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16,6 Standby Power (kW/HP) 180/241 Prime Power 163/218 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump BYC PB Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×85 Charge Alternator (A) 40 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 278 Coolant Capacity (engine only / with radiator) (lt) 12.3/41.3 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 42 Fuel Cons. Prime With %75 Load (lt/hr) 31 Fuel Cons. Prime With %50 Load (lt/hr) 21 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4150 Frequency (Hz) Hz 50 Power (kVA) kVA 187.5 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 580 COOLING AIR (m³/min) m3 30,84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 1880 2600 1250 1684 473 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) AK 49 2140 3404 1136 2020 340
200KVA GENERATOR
R645,795R645,795 Add to cart - Description General Characteristics: Model Name APD 220 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A6CRX97TI Alternator Made and Model Aksa – AK 4160 Control Panel Model DSE 6020 Canopy ASM 7 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper kVA kW kVA kW 400/231 220 176.00 200 160.00 317.55 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A6CRX97TI NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 126 X 130 TOTAL DISPLACEMENT L 9,73 Aspiration Turbo Charged and Intercooled(Water to Air) COMPRESSION RATIO 16.5:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16 Standby Power (kW/HP) 252/338 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump P pump Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×120 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 450 Coolant Capacity (engine only / with radiator) (lt) /65 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 54.1 Fuel Cons. Prime With %75 Load (lt/hr) 40.6 Fuel Cons. Prime With %50 Load (lt/hr) 27.1 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4160 Frequency (Hz) Hz 50 Power (kVA) kVA 200 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1 Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 626 COOLING AIR (m³/min) m3 30.84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ASM 7 2980 3918 1463 2163 526
220KVA GENERATOR
R650,975R650,975 Add to cart - Description General Characteristics: Model Name APD 220 C Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model CUMMINS – 6CTAA8.3-G2 Alternator Made and Model Aksa – AK 4160 Control Panel Model DSE 7320 Canopy MS 60 CK 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 220 176.00 200 160.00 317.55 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine CUMMINS Engine Model 6CTAA8.3-G2 NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 114 X 135 TOTAL DISPLACEMENT L 8,30 Aspiration Turbo Charged and Charge Air Cooled COMPRESSION RATIO 18:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 23,8 Standby Power (kW/HP) 203/272 Prime Power 183/245 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump BYC P7100 Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×85 Charge Alternator (A) 40 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 325,8 Coolant Capacity (engine only / with radiator) (lt) 12.3/47.3 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 45 Fuel Cons. Prime With %75 Load (lt/hr) 34 Fuel Cons. Prime With %50 Load (lt/hr) 23 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4160 Frequency (Hz) Hz 50 Power (kVA) kVA 200 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1 Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 626 COOLING AIR (m³/min) m3 30.84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 2300 2750 1300 1734 470 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) MS 60 CK 2930 3963 1356 2171 470
220KVA GENERATOR
R761,732R761,732 Add to cart - Description General Characteristics: Model Name AD 220 Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model HYUNDAI – P086TI Alternator Made and Model Aksa – AK 4160 Control Panel Model DSE 7320 Canopy AK 50 TRP 3 Phase, 50 Hz, PF0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 220 176.0 200 160.0 317.55 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine HYUNDAI Engine Model P086TI NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 111 X 139 TOTAL DISPLACEMENT L 8.071 Aspiration Turbo Charged and Intercooled (Air to Air) COMPRESSION RATIO 16.4:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 15.5 Standby Power (kW/HP) 199/270 Prime Power 177/240 Block Heater QTY 1 Block Heater Power (Watt) 15000 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump Zexel P inline Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×85 Charge Alternator (A) 45 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 250 Coolant Capacity (engine only / with radiator) (lt) 14/35.1 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 43.1 Fuel Cons. Prime With %75 Load (lt/hr) 31.7 Fuel Cons. Prime With %50 Load (lt/hr) 21.1 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4160 Frequency (Hz) Hz 50 Power (kVA) kVA 200 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1 Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 626 COOLING AIR (m³/min) m3 30.84 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 1830 2425 1150 1847 380 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) AK 50 TRP 2205 3404 1157 1930 380
220KVA GENERATOR
R670,052R670,052 Add to cart - Description General Characteristics: Model Name APD 250 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A6CRX97TI Alternator Made and Model Aksa – AK 4184 Control Panel Model DSE 6020 Canopy ASM 7 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 250 200 230 184 360.85 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A6CRX97TI NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 126 X 130 TOTAL DISPLACEMENT L 9,73 Aspiration Turbo Charged and Intercooled(Water to Air) COMPRESSION RATIO 16.5:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16 Standby Power (kW/HP) 252/338 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump P pump Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×120 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 450 Coolant Capacity (engine only / with radiator) (lt) /65 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 54.1 Fuel Cons. Prime With %75 Load (lt/hr) 40.6 Fuel Cons. Prime With %50 Load (lt/hr) 27.1 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4184 Frequency (Hz) Hz 50 Power (kVA) kVA 230 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 727 COOLING AIR (m³/min) m3 34,8 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ASM 7 3080 3918 1463 2163 526
250KVA GENERATOR
R640,615R640,615 Add to cart - Description General Characteristics: Model Name APD 25 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A4CRX27 Alternator Made and Model Aksa – AK 218 Control Panel Model DSE 6120 Canopy ACP 3A 3 Phase, 50Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper kVA kW kVA kW 400/231 25 20 22 17.60 36.09 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A4CRX27 NO. OF CYLINDERS AND BUILD 4 cylinders – in line BORE AND STROKE mm 90 X 105 TOTAL DISPLACEMENT L 2.672 Aspiration Naturally Aspirated COMPRESSION RATIO 18:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 6 Standby Power (kW/HP) 24.4/32.7 Prime Power 22.2/29.8 Block Heater QTY 1 Block Heater Power (Watt) 500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump Direct Governor System Mechanic Operating Voltage (Vdc) 12 Vdc Battery and Capacity (Qty/Ah) 1×36 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 84.7 Coolant Capacity (engine only / with radiator) (lt) 7/15.1 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 6.43 Fuel Cons. Prime With %75 Load (lt/hr) 5.77 Fuel Cons. Prime With %50 Load (lt/hr) 4.81 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 218 Frequency (Hz) Hz 50 Power (kVA) kVA 22,5 Design Brushless Voltage V 400 Phase 3 A.V.R. SX460 Voltage Regulation (+/-) 1,5% Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 128 COOLING AIR (m³/min) m3 5,7 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) 635 1696 892 1003 CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ACP 3A 810 1980 950 1128 60
25KVA GENERATOR
R195,613R195,613 Add to cart - Description General Characteristics: Model Name APD 275 A Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model AKSA – A6CRX97TI Alternator Made and Model Aksa – AK 4200 Control Panel Model DSE 7320 Canopy ASM 7 3 Phase, 50 Hz, PF 0.8: Voltage STANDBY RATING (ESP) PRIME RATING (PRP) Standby Ampere kVA kW kVA kW 400/231 275 220 250 200 396.94 STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed. PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour period of operation. Engine Specifications: Engine AKSA Engine Model A6CRX97TI NO. OF CYLINDERS AND BUILD 6 cylinders – in line BORE AND STROKE mm 126 X 130 TOTAL DISPLACEMENT L 9,73 Aspiration Turbo Charged and Intercooled(Water to Air) COMPRESSION RATIO 16.5:1 RATED SPEED (RPM) d/dk 1500 OIL CAPACITY L 16 Standby Power (kW/HP) 252/338 Block Heater QTY 1 Block Heater Power (Watt) 1500 Fuel Type Diesel Injection Type and System Direct Type of Fuel Pump P pump Governor System Electronic Operating Voltage (Vdc) 24 Vdc Battery and Capacity (Qty/Ah) 2×120 Cooling Method Water Cooled Cooling Fan Air Flow (m3/min) 450 Coolant Capacity (engine only / with radiator) (lt) /65 Air Filter Dry Type Fuel Cons. Prime With %100 Load (lt/hr) 54.1 Fuel Cons. Prime With %75 Load (lt/hr) 40.6 Fuel Cons. Prime With %50 Load (lt/hr) 27.1 Alternator Specifications: Manufacturer Aksa Alternator Made and Model AK 4200 Frequency (Hz) Hz 50 Power (kVA) kVA 250 Design Brushless Voltage V 400 Phase 3 A.V.R. SX440 Voltage Regulation (+/-) 1 Insulation System H Protection IP22 Rated Power Factor 0.8 WEIGHT COMP. GENERATOR (Kg) 727 COOLING AIR (m³/min) m3 34.8 Size And Weight: Open Type DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) – – – – CANOPY DRY WEIGHT (kg.) (kg.) LENGTH (mm.) WIDTH (mm.) HEIGHT (mm.) TANK CAPACITY (lt.) (Lt.) ASM 7 3080 3918 1463 2163 526
275KVA GENERATOR
R669,147R669,147 Add to cart